Secondary Injection Kit : We manufacture and supply durable varieties of Portable Over Current Relay Test Kit (Secondary Injection Kit): to fulfill wide industrial requirements of customers. These Relay Test Kit give best performance during usage and are easy to maintain. Hence, users prefer our high voltage kit to meet their entire needs. All the Voltage Relay Test Kits are available at affordable price range delivered within the expected time frame. The kits can be used for all types of relays (current and voltage relays) except distance relays. Both units are connected with common voltage, current and timer digital readout displays for accurate measurement. These kits are protected with fuses and necessary indication lamps.
Model Features- Single kit with two units
- Two separate inputs, five outputs
- Test outputs available:
Unit – I: 0 to100 A AC, 0 to 240 volts AC
Unit – II: 0 to 1 A AC, 0 to 240 volts AC and aux. 0 to 240 volts DC.
- Panel with clear and easy to follow legend
- Built in timer for testing IDMT relays, Circuit breakers
- Overload protection
- Independent digital readouts of current, voltage and time
Applications- Single pole circuit breaker timing and meters on installation and at regular services
- Quick detection of faulty or incorrectly adjusted devices during routine current/voltage injection tests
- Built in timer to measure the operating time
UNIT –ISpecificationsSupply Voltage: 230± 10% Volts, 50 / 60 Hz, AC Single Phase
Current Output- Variable current Output Application: 0 – 100A – 50A – 25A – 10A - 5A – 1A
- Each of these outputs has a separate terminal referred to one common terminal.
- RATING: 3min On/ 10 Min. Off
Voltage Output- Variable voltage output 0 – 230 V AC, (continue sly Variable)
- Constant DC output voltage: 30V & 110 V
Protection- Fuse for input and all outputs
- The timer will stop on getting the signal from the relay
- When the timer stops the current and voltage output is de – energized
Measures- Ammeter: 3 ½ Digit 12mm LED.
- Accuracy: ± 1% ± 3 digits
- Direct Reading: 0 – 100 A
- Voltmeter: 3 ½ Digit 12mm LED. Accuracy: ± 1 % ± 3 digits
- Output 1 is 0 –230 V AC, UNIT – I
- Output 2 is 0- 230 V AC, UNIT – II
- DC output 0 –250 V DC, UNIT – II
- At the time any one voltage can be read directly
Time Interval Meter: 5 Digit, 12 mm LED, crystal time base.
The timer four position selection for auto ranges
One five digit timer with toggle selector of NO/NC
for checking the opening and closing time
Multi-Range:
a) 0- 99.999 seconds
b) 999.99 seconds
c) 9999.9 seconds
d) 99999. Seconds
UNIT IISupply Voltage230± 10% Volts, 50 / 60 Hz, AC Single Phase
Current Output Variable Current Output Application: 0 – 1A
Voltage OutputContinuously Variable Voltage Output 0 – 230 V AC / DC 0.75A
Rating: Continuous
ProtectionFuse for Main Input and all Outputs
Selection (Mode)All output is connected through by – pass/control mode switch
By - Pass ModeIf by pass mode is chosen, then all output will be directly connected to the output terminals (In this option timer is Off mode)
Control ModePush button control mode is chosen then all output will be connected to the output terminals when the On/Off push button is operated (In this option timer is On mode)
ConstructionPowder Coated MS Box, Carrying Handle.
DimensionsW x D x H: 17.5” x 13” x 7.5” approx.
Weight23 kegs. Approx
*Each of these outputs has a separate pair of terminals